Fundamentals
of Troubleshooting – Electronics & Photonics By Daniel J.M. Guibord Proper test and measurement instrumentation for the type of
equipment that you are troubleshooting is a must. With today’s circuitry, at
minimum you need an oscilloscope. A multimeter is to the electronics &
photonics technician what a blindman’s cane is to a blind person. An
oscilloscope is your eyes.
All electronic equipment can be divided into two fundamental
blocks: ·
The power supply ·
The electronic circuitry fed by the power supply First, conduct a visual inspection of the electronic
circuitry’s components. Look for signs of overheated or burnt components.
Then, verify the integrity of the power supply’s voltages. Begin at the
input(s) of the power supply, and work your way to the output(s). If
the supply’s voltages do not check out OK, disconnect it from the electronic
circuitry that it feeds, the measured voltages’ values will give you a clear
answer as to whether the problem is with the power supply, or with the
electronic circuitry fed by it. If the supply’s voltages check out OK*, then apply a signal (or signals) to
the input(s) of the electronic circuitry and trace the flow to the output(s).
Look for the signal at about half way between input(s) and output(s), it will
determine which direction you need to go from that point on, forward or
backward. Use the half way approach again (e.g., say the signal was not present
half way between an input and output, go half way between these two points
now, and so on, until you reach a point where the signal is OK on one side of
a circuit’s node, and not OK on the other side of that same node). Wherever
the signal is not what it should be, that is where the problem is. Now you
have to narrow it down to the component level, right? Perhaps not. It depends
on the dollar value of the components where the signal that you were tracing
got lost or altered. It is up to you to judge the situation. If the
components involved are worth less than $10, simply replace all components in
the vicinity where the signal got altered (how much is your time worth?). [*There is however a relatively infrequent case where the
output voltages of the power supply unit are correct without load, but
incorrect under load. It may turn out appropriate to test the power supply
unit with a suitable load in order to eliminate this possibility.] However, once you verified the integrity of the power supply,
there are a few things that you can check before spending your time tracing
signals through myriads of components. You should bear in mind that: ·
70% of failures of electronic equipment are due to metallic
contacts (e.g., oxidation of switches, connectors and relay’s contacts,
potentiometers’ wipers, etc.). ·
20% of failures are due to semiconductors. Those which fail
most often are: o
Power devices o
Peripheral chips (chips located typically at the inputs
and outputs of a circuit block). ·
5% of failures are due to capacitors, either opened or
shorted; or worst, leaking or slightly out of specifications. ·
2% of failures are due to resistors (opened in the vast
majority of cases). ·
1% of failures are due to drifts in components’ values. ·
1% of failures are due to borderline engineering (a diplomatic
word for quack engineering). ·
1% of failures are due to a number of causes usually not easy
or obvious to pin down, which, in most cases, result in intermittent
problems. These are, typically: o
1- Electrical noise conducted or radiated. o
2- Mechanical vibrations. o 3- Cold solders. If you suspect a cold
solder, do not try to pin down exactly which solder joint is the culprit,
simply resolder every solder joint in the vicinity, unless you want to spend
an inordinate amount of time searching for what may turn out to be, in the
end of it all, a metallization pad’s problem inside an integrated circuit. |